Customization: | Available |
---|---|
Application Fields: | Medical |
Certification: | CCC, CE, ISO |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
hot sale automatic medical gas manifold
The hot sale automatic medical gas manifold can realize automatic switching without any adjustment by the operator, and it can still work normally even when the electrical system is powered off.
* Display: 7" HD LCD touchscreen
* Cabinet with door:
Material - Galvanized steel
Dimensions - 80x100x25 cm
Finish - baked on powder coated
Piping System: All materials are oxygen compatible and cleaned for oxygen use.
* Changeover Unit: Pneumatic.
*Flow Capacity: 4 Bar- 90 m3/hr.
* 8 bar- 120 m3/hr.
* Power Supply: 110-220V, 60-50Hz.
* Each cylinder station includes an HP valve, pigtail with integrated NRV and a secure chain.
* An electrical power supply unit was installed on the external side of the cabinet.
The unit enables the connection of 2 supplies:
* Supply from the mains / essential / UPS
* Supply from batteries (Optional)
* Output connections for area alarms:
Two sets of dry contacts NO/ NC.
* Connection: TCP/ IP Modbus.
* Optional:
Heaters (for N2O or CO2).
Bank heavy-duty high-pressure filters.
Gas | Input Pressure mpa(psi) |
Output Pressure mpa(psi) |
Output Flow m3/h |
Power |
O2 | 15(2175) | 0.07-1(10-145) | 100 | 220v, 50hz |
C2H2 | 3(435) | 0.01-0.1(1.5-15) | 20 | 220v, 50hz |
C3H8 | 3(435) | 0.03-0.85(4.4-125) | 60 | 220v, 50hz |
CO2 | 15(2175) | 0.03-0.85(4.4-125) | 60 | 220v, 50hz |
Ar | 15(2175) | 0.07-1.4(10-203) | 90 | 220v, 50hz |
He | 15(2175) | 0.07-1.4(10-203) | 250 | 220v, 50hz |
N2 | 15(2175) | 0.07-1.4(10-203) | 105 | 220v, 50hz |
Air | 15(2175) | 0.07-1.4(10-203) | 105 | 220v, 50hz |
N2O | 15(2175) | 0.07-1.4(10-203) | 60 | 220v, 50hz |
Features:
1. CE certification.
2, Automatic switching, strong and weak electricity separation.
3. On-site signal lights indicate working status, pressure gauges display pressure, with sound and light alarm function.
4. Secondary pressure regulator and pressure reducer for one backup and one use.
5. Continuous gas supply and automatic switching after power failure, it is not necessary to close the gas supply pipeline during maintenance.
6. Touch screen, PLC control.
7. With temperature control to prevent frost and overheating and leakage.
8. The pipeline adopts the form of live connection, which is more convenient for maintenance.
9. Reliable wall installation or horizontal installation.
10. Valves and pipes are made of 316L BA grade stainless steel, with high cleanliness.
11. Pilot-operated control switching gas path, pressure is stable.
Zone Valve Box |
Gas Regulator Box |
Monitoring alarm box
|
1,Used to control the on and off of medical gases in the area; 2,1~6 channels of medical gas can be controlled according to user requirements; 3,Silver and copper welding to prevent leakage; 4,Transparent window for easy operation and maintenance; 5,Each gas is marked with a national standard color for easy identification. |
1,Used to provide a pressure-stable source of gas for the clinic; 2,With dual circuit design, it can be maintained without stopping the gas; 3,Use a large flow reducer to ensure pressure stability; 4,Emergency door lock device to close the valve in an emergency; 5,Transparent window for easy operation and maintenance; |
1,Monitor the pressure of the gas supply, and the pressure is high or low to alarm; 2,Monitor the moisture content/oxygen concentration/CO content in oxygen , giving alarm against any deviation from standard set value. Powerful data post-processing function, real-time storage history; 3,intelligent monitoring, with remote data transfer function; |
Medical Gas Supply System Gas Management
The pressure monitoring alarm box is used to monitor the pipeline pressure of the medical center air supply system and respond to pressure changes through a digital microprocessor. When the pressure is higher or lower than the set value, the system will automatically alarm by sound and light, etc., to remind the management to timely process the medical center air supply system.
Comprehensive data collection: monitoring of the source gases and gas-consuming areas in the hospital.
Central monitoring: central monitoring of gas sources and gas-consuming areas, enabling comprehensive data browsing and operation curve analysis.
Fault early warning: abnormal data analysis and trend analysis.
Q: Are you factory or trading company?
A: We are factory specilized in making hot sale automatic medical gas manifold from year 2003.
Q: Where are you?
A: We are in ChangSha,Hunan province,3 hours from guangzhou by high-speed rail.
Q: Do you accept the small order?
A: Yes, you can contact with us.
Q: Can we put our logo on your products?
A: Yes, we can customized your logo. But the quantity of the items have special requirements.
Q: What certifications do products have for your company?
A: CE, ISO and SGS at present.
Q: Do you provide technical support?
A: Yes, technical support is available after sales,if needed,we will provide our technicist to overseas to service you.