Customization: | Available |
---|---|
After-sales Service: | One Year |
Warranty: | One Year |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
Scroll and reciprocant oil free compresors with desiccant air dryer |
1. Description
The compressed air is generated by the air compressor, enters the gas storage tank through the aftercooler, and then removes impurities, oil mist and moisture in the compressed air through the filter group and the adsorption dryer, and then is regulated by the pressure reducer. Compressed air ducts are used in medical equipment such as operating rooms and ICUs.
The central compressed air station is composed of an air compressor, an aftercooler, a gas storage tank, a filter group, an adsorption dryer, an automatic control cabinet, and an alarm. Usually it is a two-unit configuration, one for each.
2. Why use dry, clean compressed air?
IInhibit the survival and reproduction of bacteria
Prevent condensation into liquid water at low temperatures
Liquid water will damage these equipment after entering the anesthesia machine or ventilator
Prevent icing blocked pipes below zero
High humidity in the pipe can cause oxidation of the pipe
3. Advantage
1.Oil-free design, ensuring the generation of qualified medical air
2.Reduced equipment failure frequency, saving costs
3.Controlled moisture content, achieving high safety performance
4. ETR Hospital Compressed Air Generator Working Principle
4.1 Medical Compressed Air Station System Specifications
System Model | Air Compressor | Purification controller | Air tanks (M3) | Output Consumption (M3/min) | Output Pressure (Mpa) | ||
Model | Number | Model | Number | ||||
ETA-04 | ET-YA041 | 1 | ET-YK15 | 1 | 0.3 | 0.41 | 0.4-0.6 |
ETA-07 | ET-YA042 | 1 | ET-YK15 | 1 | 0.3 | 0.82 | 0.4-0.6 |
ETA-11 | ET-YA043 | 1 | ET-YK26 | 1 | 0.6 | 1.23 | 0.4-0.6 |
ETA-15 | ET-YA042 | 2 | ET-YK26 | 1 | 0.6 | 1.64 | 0.4-0.6 |
ETA-22 | ET-YA043 | 2 | ET-YK38 | 1 | 1 | 2.46 | 0.4-0.6 |
ETA-30 | ET-YA043 | 3 | ET-YK38 | 1 | 1 | 3.69 | 0.4-0.6 |
4.2 Air Compressor Specifications
Model |
Output Consumption (M3/min) |
Working pressure (Mpa) | Power |
Power (KW) |
L*W*H(mm) | Weight(KG) | Noise(dB) |
ET-YA041 | 0.41 | 0.6-0.8 | AC380V/50Hz/3P | 4 | 1300×700×750 | 170 | 65±3 |
ET-YA042 | 0.82 | 0.6-0.8 | AC380V/50Hz/3P | 8 | 1300×700×1350 | 255 | 65±3 |
ET-YA043 | 1.23 | 0.6-0.8 | AC380V/50Hz/3P | 12 | 1300×700×1950 | 345 | 65±3 |
4.3 Purification Controller Specifications
Model | Capacity (M3/min) | Working pressure (Mpa) | Power |
Power (KW) |
Dew Point (ºC) | Weight (KG) | L*W*H(mm) | Noise(dB) |
ET-YK15 | 1.5 | 0.6-0.8 | AC220V/50Hz | 30 | </=-40 | 356 | 1300×900×1700 | </=75 |
ET-YK26 | 2.6 | 0.6-0.8 | AC220V/51Hz | 30 | </=-40 | 374 | 1300×900×1700 | </=75 |
ET-YK38 | 3.8 | 0.6-0.8 | AC220V/52Hz | 30 | </=-40 | 412 | 1300×900×1700 | </=75 |
5. Quality Control Process
ETR Enigineering & Technology,clients can be sure of the quality of ETR solution. ETR uses only the best suppliers and components. And all compress air system are tested & commissioned by professional Experts to make sure everything is qualified before they leave the factory.
1. Are you manufacturer or Trade Company?
We are the manufacturer of compress air system, founded in 2003.
2. What's the order compress air system process?
a. Inquiry---provide us all clear requirements.
b. Quotation---official quotation form with all clear specifications.
c. Printing file--- PDF, Ai, CDR, PSD, the picture resolution must be at least 300 dpi.
d. Contract confirmation---provide correct contract details.
e. Payment terms--- Negotiable.
f. Production---mass production
g. Shipping--- by sea, air or courier. Detailed picture of package will be provided.
h. Installation and commissioning
3.What terms of payment you use?
T/T, L/C etc.