Customization: | Available |
---|---|
Application Fields: | Medical |
Certification: | CCC, CE, ISO |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
automatic medical gas manifold system Medical Gas Manifold - Cylinder-by-Cylinder
Introducing the ETR Medical Genesys Cylinder by Cylinder Medical Gas Manifold, a breakthrough in reliable and efficient medical gas supply. This advanced manifold system is an essential tool for any healthcare facility that depends on the regular use of medical gases.
A medical gas manifold is a device that is used to distribute medical gases to various points of use within a hospital or other healthcare setting. It is typically installed in a central location, such as a utility room or supply closet, and is connected to the main medical gas supply line. The manifold has a series of outlets, which are connected to individual gas outlets or terminal units throughout the healthcare facility. This allows the medical gases to be distributed to the various areas where they are needed, such as patient rooms, operating theaters, and other areas. The manifold is an important part of the overall medical gas system and helps to ensure that patients have access to the gases they need for treatment.
ETR medical gas manifold systems lead the industry in reliability and innovative features: transducers instead of pressure switches, 400 PSIG pressure differential rated solenoid valve(s), easy-to-service 2D layouts, and union fittings before and after all serviceable components. In addition, they are designed to allow the medical gas manifold cabinet to be converted in the field (i.e.- from standard flow to high flow or from cylinder-by-cylinder use to liquid-by-cylinder or liquid-by-liquid). These design features: improve safety, reduce manifold system costs, make the units easy to service, and provide the utmost reliability.
The hot sale automatic medical gas manifold can realize automatic switching without any adjustment by the operator, and it can still work normally even when the electrical system is powered off.
The ETR Manifold incorporates the basic necessities for distributing and monitoring medical gas throughout a facility.
This automatic changeover unit is designed for a continuous supply of gas at the pressure of up to 8 bars (higher outlet pressure upon customer request) and includes a mechanism that switches the supply from the "in service" bank to a "reserve" supply bank when the "in service" bank is empty.
Gas | Input Pressure mpa(psi) |
Output Pressure mpa(psi) |
Output Flow m3/h |
Power |
O2 | 15(2175) | 0.07-1(10-145) | 100 | 220v, 50hz |
C2H2 | 3(435) | 0.01-0.1(1.5-15) | 20 | 220v, 50hz |
C3H8 | 3(435) | 0.03-0.85(4.4-125) | 60 | 220v, 50hz |
CO2 | 15(2175) | 0.03-0.85(4.4-125) | 60 | 220v, 50hz |
Ar | 15(2175) | 0.07-1.4(10-203) | 90 | 220v, 50hz |
He | 15(2175) | 0.07-1.4(10-203) | 250 | 220v, 50hz |
N2 | 15(2175) | 0.07-1.4(10-203) | 105 | 220v, 50hz |
Air | 15(2175) | 0.07-1.4(10-203) | 105 | 220v, 50hz |
N2O | 15(2175) | 0.07-1.4(10-203) | 60 | 220v, 50hz |
Features:
1. CE certification.
2, Automatic switching, strong and weak electricity separation.
3. On-site signal lights indicate working status, pressure gauges display pressure, with sound and light alarm function.
4. Secondary pressure regulator and pressure reducer for one backup and one use.
5. Continuous gas supply and automatic switching after power failure, it is not necessary to close the gas supply pipeline during maintenance.
6. Touch screen, PLC control.
7. With temperature control to prevent frost and overheating and leakage.
8. The pipeline adopts the form of live connection, which is more convenient for maintenance.
9. Reliable wall installation or horizontal installation.
10. Valves and pipes are made of 316L BA grade stainless steel, with high cleanliness.
11. Pilot-operated control switching gas path, pressure is stable.
* The ETR Automatic changeover unit is designed for a continuous supply
of gas at a pressure of up to 8 bars(higher outlet pressure upon customer request).
* The panel includes a mechanism which switches the supply from the "in-service"
bank to a "reserve" supply bank, when the "in service" bank is empty. After rotating the
lever and replace the empty bank cylinders, the previous "in service" becomes
the "reserve" bank for the next operation.
* The panel is equipped with two manifold pressure regulators (in case of malfunction),
mid-range gauge, line pressure regulators w/bypass valves, all mounted on
a white baked painted steel panel.
* Safety valve @ 6bar supplied with the panel.
Zone Valve Box |
Gas Regulator Box |
Monitoring alarm box
|
1,Used to control the on and off of medical gases in the area; 2,1~6 channels of medical gas can be controlled according to user requirements; 3,Silver and copper welding to prevent leakage; 4,Transparent window for easy operation and maintenance; 5,Each gas is marked with a national standard color for easy identification. |
1,Used to provide a pressure-stable source of gas for the clinic; 2,With dual circuit design, it can be maintained without stopping the gas; 3,Use a large flow reducer to ensure pressure stability; 4,Emergency door lock device to close the valve in an emergency; 5,Transparent window for easy operation and maintenance; |
1,Monitor the pressure of the gas supply, and the pressure is high or low to alarm; 2,Monitor the moisture content/oxygen concentration/CO content in oxygen , giving alarm against any deviation from standard set value. Powerful data post-processing function, real-time storage history; 3,intelligent monitoring, with remote data transfer function; |
Medical Gas Supply System Gas Management
The pressure monitoring alarm box is used to monitor the pipeline pressure of the medical center air supply system and respond to pressure changes through a digital microprocessor. When the pressure is higher or lower than the set value, the system will automatically alarm by sound and light, etc., to remind the management to timely process the medical center air supply system.
Comprehensive data collection: monitoring of the source gases and gas-consuming areas in the hospital.
Central monitoring: central monitoring of gas sources and gas-consuming areas, enabling comprehensive data browsing and operation curve analysis.
Fault early warning: abnormal data analysis and trend analysis.
Q: Are you factory or trading company?
A: We are factory specilized in making automatic medical gas manifold system from year 2003.
Q: Where are you?
A: We are in ChangSha,Hunan province,3 hours from guangzhou by high-speed rail.
Q: Do you accept the small order?
A: Yes, you can contact with us.
Q: Can we put our logo on your products?
A: Yes, we can customized your logo. But the quantity of the items have special requirements.
Q: What certifications do products have for your company?
A: CE, ISO and SGS at present.
Q: Do you provide technical support?
A: Yes, technical support is available after sales,if needed,we will provide our technicist to overseas to service you.