Reliable Automatic Medical Gas Manifold Solution for Patient Care

Product Details
Customization: Available
Application Fields: Medical
Certification: CCC, CE, ISO
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
32000000 RMB
Plant Area
>2000 square meters
  • Reliable Automatic Medical Gas Manifold Solution for Patient Care
  • Reliable Automatic Medical Gas Manifold Solution for Patient Care
  • Reliable Automatic Medical Gas Manifold Solution for Patient Care
  • Reliable Automatic Medical Gas Manifold Solution for Patient Care
  • Reliable Automatic Medical Gas Manifold Solution for Patient Care
  • Reliable Automatic Medical Gas Manifold Solution for Patient Care
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
ETBX
Condition
New
Noise Level
Low
Parts
Gas Tank
Purpose
Gas Separation
Structure
Horizontal
Types
Air separation equipment
Working principle
Adsorption separation
Color
White
Application
Medical
Certificate
CE, ISO, SGS
Warranty
One Year
Name
Factory Price Medical Gas Manifold
Packing
Export Standard Packing
Function
Hospital Medical Gas Supply
Service
Assign Engineer for Onsite Instruction
Power
220V, 50Hz
Type
Automatic
Usage
Hydrogen, Nitrogen, Oxygen, Ozone
Machine Size
Medium
Transport Package
Wooden Case
Specification
Actual Size
Trademark
ETR
Origin
Changsha China
HS Code
8419601900
Production Capacity
200 Set

Product Description


automatic medical gas manifold system  Medical Gas Manifold - Cylinder-by-Cylinder

Product Description

 


 

Introducing the ETR Medical Genesys Cylinder by Cylinder Medical Gas Manifold, a breakthrough in reliable and efficient medical gas supply. This advanced manifold system is an essential tool for any healthcare facility that depends on the regular use of medical gases.
Reliable Automatic Medical Gas Manifold Solution for Patient Care

medical gas manifold is a device that is used to distribute medical gases to various points of use within a hospital or other healthcare setting. It is typically installed in a central location, such as a utility room or supply closet, and is connected to the main medical gas supply line. The manifold has a series of outlets, which are connected to individual gas outlets or terminal units throughout the healthcare facility. This allows the medical gases to be distributed to the various areas where they are needed, such as patient rooms, operating theaters, and other areas. The manifold is an important part of the overall medical gas system and helps to ensure that patients have access to the gases they need for treatment.

ETR medical gas manifold systems lead the industry in reliability and innovative features: transducers instead of pressure switches, 400 PSIG pressure differential rated solenoid valve(s), easy-to-service 2D layouts, and union fittings before and after all serviceable components. In addition, they are designed to allow the medical gas manifold cabinet to be converted in the field (i.e.- from standard flow to high flow or from cylinder-by-cylinder use to liquid-by-cylinder or liquid-by-liquid). These design features: improve safety, reduce manifold system costs, make the units easy to service, and provide the utmost reliability.


The hot sale automatic medical gas manifold can realize automatic switching without any adjustment by the operator, and it can still work normally even when the electrical system is powered off.

The ETR Manifold incorporates the basic necessities for distributing and monitoring medical gas throughout a facility. 

This automatic changeover unit is designed for a continuous supply of gas at the pressure of up to 8 bars (higher outlet pressure upon customer request) and includes a mechanism that switches the supply from the "in service" bank to a "reserve" supply bank when the "in service" bank is empty.


Reliable Automatic Medical Gas Manifold Solution for Patient Care

Gas Input Pressure
mpa(psi)
Output Pressure
mpa(psi)
Output Flow
m3/h
Power
O2 15(2175) 0.07-1(10-145) 100 220v, 50hz
C2H2 3(435) 0.01-0.1(1.5-15) 20 220v, 50hz
C3H8 3(435) 0.03-0.85(4.4-125) 60 220v, 50hz
CO2 15(2175) 0.03-0.85(4.4-125) 60 220v, 50hz
Ar 15(2175) 0.07-1.4(10-203) 90 220v, 50hz
He 15(2175) 0.07-1.4(10-203) 250 220v, 50hz
N2 15(2175) 0.07-1.4(10-203) 105 220v, 50hz
Air 15(2175) 0.07-1.4(10-203) 105 220v, 50hz
N2O 15(2175) 0.07-1.4(10-203) 60 220v, 50hz

Features:

1. CE certification.
2, Automatic switching, strong and weak electricity separation.
3. On-site signal lights indicate working status, pressure gauges display pressure, with sound and light alarm function.
4. Secondary pressure regulator and pressure reducer for one backup and one use.
5. Continuous gas supply and automatic switching after power failure, it is not necessary to close the gas supply pipeline during maintenance.
6. Touch screen, PLC control.
7. With temperature control to prevent frost and overheating and leakage.
8. The pipeline adopts the form of live connection, which is more convenient for maintenance.
9. Reliable wall installation or horizontal installation.

10. Valves and pipes are made of 316L BA grade stainless steel, with high cleanliness.
11. Pilot-operated control switching gas path, pressure is stable.
Reliable Automatic Medical Gas Manifold Solution for Patient Care

*  The ETR Automatic changeover unit is designed for a continuous supply
     of gas
 at a pressure of up to 8 bars(higher outlet pressure upon customer request).

*  The panel includes a mechanism which switches the supply from the "in-service"
     bank to a "reserve" supply bank, when the "in service" bank is empty. After rotating the
     lever and replace the empty bank cylinders, the previous "in service" becomes
     the "reserve" bank for the next operation.

*  The panel is equipped with two manifold pressure regulators (in case of malfunction),
    mid-range gauge, line pressure 
regulators w/bypass valves, all mounted on
    a white baked painted steel panel.

*  Safety valve @ 6bar supplied with the panel.


THE INTEGRATED SOLUTIONS FOR MEDICAL GAS SYSTEM
Reliable Automatic Medical Gas Manifold Solution for Patient Care


Medical Gas Supply System Fittings 
Zone Valve Box
Reliable Automatic Medical Gas Manifold Solution for Patient Care
 Gas Regulator Box
Reliable Automatic Medical Gas Manifold Solution for Patient Care

 Monitoring alarm box
Reliable Automatic Medical Gas Manifold Solution for Patient Care

 

 

 

1,Used to control the on and off of medical gases in the area;

2,1~6 channels of medical gas can be controlled according to user requirements;

3,Silver and copper welding to prevent leakage;

4,Transparent window for easy operation and maintenance;

5,Each gas is marked with a national standard color for easy identification.

1,Used to provide a pressure-stable source of gas for the clinic;

2,With dual circuit design, it can be maintained without stopping the gas;

3,Use a large flow reducer to ensure pressure stability;

4,Emergency door lock device to close the valve in an emergency;

5,Transparent window for easy operation and maintenance;

 

1,Monitor the pressure of the gas supply, and the pressure is high or low to alarm;

2,Monitor the moisture content/oxygen concentration/CO content in oxygen , giving alarm against any deviation from standard set value. Powerful data post-processing function, real-time storage history;

3,intelligent monitoring, with remote data transfer function;

 

 

Medical Gas Supply System Gas Management

The pressure monitoring alarm box is used to monitor the pipeline pressure of the medical center air supply system and respond to pressure changes through a digital microprocessor. When the pressure is higher or lower than the set value, the system will automatically alarm by sound and light, etc., to remind the management to timely process the medical center air supply system.

Reliable Automatic Medical Gas Manifold Solution for Patient Care



Comprehensive data collection: monitoring of the source gases and gas-consuming areas in the hospital.
Reliable Automatic Medical Gas Manifold Solution for Patient Care
Central monitoring: central monitoring of gas sources and gas-consuming areas, enabling comprehensive data browsing and operation curve analysis.
Reliable Automatic Medical Gas Manifold Solution for Patient Care
Fault early warning: abnormal data analysis and trend analysis.
Reliable Automatic Medical Gas Manifold Solution for Patient Care


Warranty
The Guarantee/Warranty Period shall be a period of twelve months after on-site startup & commissioning or eighteen months after shipment, whichever occurs first. If any trouble or defect, originating with the design, material, workmanship or operating characteristics of any Goods, arises at any time during GUARANTEE/WARRANTY period, ETR shall, at his own expense and as promptly as possible, make such alterations, repairs and replacements.
On-Site Support
ETR can do paid services of on-site startup, commissioning, installation supervision, training, by providing purchaser with the services of qualified English-speaking
engineer at site. ETR shall obtain all permits and licenses required to perform the services under this Agreement. 

Reliable Automatic Medical Gas Manifold Solution for Patient CareReliable Automatic Medical Gas Manifold Solution for Patient Care

FAQ:

Q: Are you factory or trading company?
A: We are factory specilized in making automatic medical gas manifold system from year 2003.

Q: Where are you?
A: We are in ChangSha,Hunan province,3 hours from guangzhou by high-speed rail.

Q: Do you accept the small order?
A: Yes, you can contact with us.

Q: Can we put our logo on your products?
A: Yes, we can customized your logo. But the quantity of the items have special requirements.
 
Q: What certifications do products have for your company?
A: CE, ISO and SGS at present.

Q: Do you provide technical support?
A: Yes, technical support is available after sales,if needed,we will provide our technicist to overseas to service you.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier