High Safety Level Hospital Oxygen Manifold System Fully Automatic Digital Medical Gas Manifold

Product Details
Customization: Available
Application Fields: Medical
Certification: CCC, CE, ISO
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
32000000 RMB
Plant Area
>2000 square meters
  • High Safety Level Hospital Oxygen Manifold System Fully Automatic Digital Medical Gas Manifold
  • High Safety Level Hospital Oxygen Manifold System Fully Automatic Digital Medical Gas Manifold
  • High Safety Level Hospital Oxygen Manifold System Fully Automatic Digital Medical Gas Manifold
  • High Safety Level Hospital Oxygen Manifold System Fully Automatic Digital Medical Gas Manifold
  • High Safety Level Hospital Oxygen Manifold System Fully Automatic Digital Medical Gas Manifold
  • High Safety Level Hospital Oxygen Manifold System Fully Automatic Digital Medical Gas Manifold
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
ETAB
Condition
New
Noise Level
Low
Parts
Gas Tank
Purpose
Gas Separation
Structure
Horizontal
Color
White
Application
Medical
Certificate
CE, ISO, SGS
Warranty
One Year
Name
High Safety Level Hospital Oxygen Manifold System
Packing
Export Standard Packing
Function
Hospital Medical Gas Supply
Service
Assign Engineer for Onsite Instruction
Power
220V, 50Hz
Type
Automatic
Usage
Hydrogen, Nitrogen, Oxygen, Ozone
Machine Size
Medium
Transport Package
Wooden Case
Specification
Actual Size
Trademark
ETR
Origin
Changsha China
HS Code
8419601900
Production Capacity
200 Set

Product Description


high safety level hospital oxygen manifold system Fully Automatic Digital Medical Gas Manifold

Product Description

 

The ETR Fully Automatic Medical Gas Manifold system is a new approach to medical gas management. It employs advanced electronic system technology that redefines the state-of-art for modern healthcare facilities.

We designed this system to be reliable and to supply continuous gas flow and smooth automatic bank switchover by means of a pneumatic shuttle valve.

The manifold is designed for backups or as a main supply system where central systems are not available.   


The high safety level hospital oxygen manifold system can realize automatic switching without any adjustment by the operator, and it can still work normally even when the electrical system is powered off.
 

Continuous supply and smooth automatic bank switchover, without pressure fluctuation, by means of a pneumatic shuttle valve.

Maintenance friendly- designed to enable maintenance during operation without the need to disrupt the gas supply.

LCD 7" touch screen display.

Graphically & digitally display the actual status of each source- "In use" or "Stand by".

* Visual & audio alarm signals in case of change between banks, "Below min" and High/Low line supply pressure.

* Leak detection from manifolds on Stand-By mode.

Secured Ethernet-based network communication between all units.

*Unique secured authentication of each unit to avoid fake/masking of alarms.

A color trend arc showing the gas pressure status on the main line and at each bank

Optional- display of heaters during idle and active states.

Automatic adjustment of screen brightness(day & night mode).

Event logging, recording all alarms and panel activities.

Periodical maintenance alert.

Customizable text & language.

Alarm test & mute buzzer buttons.

* Advanced Communication:
   Ethernet Modbus/Remote monitoring through the building
    management system available.
   Option for remote viewing through a mobile device or remote computer


High Safety Level Hospital Oxygen Manifold System Fully Automatic Digital Medical Gas Manifold

Gas Input Pressure
mpa(psi)
Output Pressure
mpa(psi)
Output Flow
m3/h
Power
O2 15(2175) 0.07-1(10-145) 100 220v, 50hz
C2H2 3(435) 0.01-0.1(1.5-15) 20 220v, 50hz
C3H8 3(435) 0.03-0.85(4.4-125) 60 220v, 50hz
CO2 15(2175) 0.03-0.85(4.4-125) 60 220v, 50hz
Ar 15(2175) 0.07-1.4(10-203) 90 220v, 50hz
He 15(2175) 0.07-1.4(10-203) 250 220v, 50hz
N2 15(2175) 0.07-1.4(10-203) 105 220v, 50hz
Air 15(2175) 0.07-1.4(10-203) 105 220v, 50hz
N2O 15(2175) 0.07-1.4(10-203) 60 220v, 50hz

Features:

1. CE certification.
2, Automatic switching, strong and weak electricity separation.
3. On-site signal lights indicate working status, pressure gauges display pressure, with sound and light alarm function.
4. Secondary pressure regulator and pressure reducer for one backup and one use.
5. Continuous gas supply and automatic switching after power failure, it is not necessary to close the gas supply pipeline during maintenance.
6. Touch screen, PLC control.
7. With temperature control to prevent frost and overheating and leakage.
8. The pipeline adopts the form of live connection, which is more convenient for maintenance.
9. Reliable wall installation or horizontal installation.

10. Valves and pipes are made of 316L BA grade stainless steel, with high cleanliness.
11. Pilot-operated control switching gas path, pressure is stable.
High Safety Level Hospital Oxygen Manifold System Fully Automatic Digital Medical Gas Manifold




THE INTEGRATED SOLUTIONS FOR MEDICAL GAS SYSTEM
High Safety Level Hospital Oxygen Manifold System Fully Automatic Digital Medical Gas Manifold


Medical Gas Supply System Fittings 
Zone Valve Box
High Safety Level Hospital Oxygen Manifold System Fully Automatic Digital Medical Gas Manifold
 Gas Regulator Box
High Safety Level Hospital Oxygen Manifold System Fully Automatic Digital Medical Gas Manifold

 Monitoring alarm box
High Safety Level Hospital Oxygen Manifold System Fully Automatic Digital Medical Gas Manifold

 

 

 

1,Used to control the on and off of medical gases in the area;

2,1~6 channels of medical gas can be controlled according to user requirements;

3,Silver and copper welding to prevent leakage;

4,Transparent window for easy operation and maintenance;

5,Each gas is marked with a national standard color for easy identification.

1,Used to provide a pressure-stable source of gas for the clinic;

2,With dual circuit design, it can be maintained without stopping the gas;

3,Use a large flow reducer to ensure pressure stability;

4,Emergency door lock device to close the valve in an emergency;

5,Transparent window for easy operation and maintenance;

 

1,Monitor the pressure of the gas supply, and the pressure is high or low to alarm;

2,Monitor the moisture content/oxygen concentration/CO content in oxygen , giving alarm against any deviation from standard set value. Powerful data post-processing function, real-time storage history;

3,intelligent monitoring, with remote data transfer function;

 

 

Medical Gas Supply System Gas Management

The pressure monitoring alarm box is used to monitor the pipeline pressure of the medical center air supply system and respond to pressure changes through a digital microprocessor. When the pressure is higher or lower than the set value, the system will automatically alarm by sound and light, etc., to remind the management to timely process the medical center air supply system.

High Safety Level Hospital Oxygen Manifold System Fully Automatic Digital Medical Gas Manifold



Comprehensive data collection: monitoring of the source gases and gas-consuming areas in the hospital.
High Safety Level Hospital Oxygen Manifold System Fully Automatic Digital Medical Gas Manifold
Central monitoring: central monitoring of gas sources and gas-consuming areas, enabling comprehensive data browsing and operation curve analysis.
High Safety Level Hospital Oxygen Manifold System Fully Automatic Digital Medical Gas Manifold
Fault early warning: abnormal data analysis and trend analysis.
High Safety Level Hospital Oxygen Manifold System Fully Automatic Digital Medical Gas Manifold


Warranty
The Guarantee/Warranty Period shall be a period of twelve months after on-site startup & commissioning or eighteen months after shipment, whichever occurs first. If any trouble or defect, originating with the design, material, workmanship or operating characteristics of any Goods, arises at any time during GUARANTEE/WARRANTY period, ETR shall, at his own expense and as promptly as possible, make such alterations, repairs and replacements.
On-Site Support
ETR can do paid services of on-site startup, commissioning, installation supervision, training, by providing purchaser with the services of qualified English-speaking
engineer at site. ETR shall obtain all permits and licenses required to perform the services under this Agreement. 

High Safety Level Hospital Oxygen Manifold System Fully Automatic Digital Medical Gas ManifoldHigh Safety Level Hospital Oxygen Manifold System Fully Automatic Digital Medical Gas Manifold

FAQ:

Q: Are you factory or trading company?
A: We are factory specilized in making high safety level hospital oxygen manifold system from year 2003.

Q: Where are you?
A: We are in ChangSha,Hunan province,3 hours from guangzhou by high-speed rail.

Q: Do you accept the small order?
A: Yes, you can contact with us.

Q: Can we put our logo on your products?
A: Yes, we can customized your logo. But the quantity of the items have special requirements.
 
Q: What certifications do products have for your company?
A: CE, ISO and SGS at present.

Q: Do you provide technical support?
A: Yes, technical support is available after sales,if needed,we will provide our technicist to overseas to service you.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier