BS Type Oxygen, Vacuum, and Medical Air Gas Supply Outlets

Product Details
Customization: Available
Customized: Customized
Certification: CE, ISO13485
Manufacturer/Factory

360° Virtual Tour

Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
32000000 RMB
Plant Area
>2000 square meters
  • BS Type Oxygen, Vacuum, and Medical Air Gas Supply Outlets
  • BS Type Oxygen, Vacuum, and Medical Air Gas Supply Outlets
  • BS Type Oxygen, Vacuum, and Medical Air Gas Supply Outlets
  • BS Type Oxygen, Vacuum, and Medical Air Gas Supply Outlets
  • BS Type Oxygen, Vacuum, and Medical Air Gas Supply Outlets
  • BS Type Oxygen, Vacuum, and Medical Air Gas Supply Outlets
Find Similar Products

Basic Info.

Scale
Small
Type
Medical Call System
Product Name
Medical Gas Terminal Units
OEM/ODM
Acceptable
Cerification
CE, ISO
Color
All Color Customized
Gas
Oxygen, Nitrogen, VAC and Customized
Specific Use
Bed Head Unit
Connection Method
Connector/ Adapter
Sample
Available
Certificate
CE ISO
Transport Package
Wooden Case
Trademark
ETR
Origin
Changsha China
HS Code
8419601900
Production Capacity
200 Set

Product Description

BS type oxygen, vacuum, and medical air gas supply outlets
BS Type Oxygen, Vacuum, and Medical Air Gas Supply Outlets
Features:
  1. British Standard/German Standar/Japanese Standard/France Standard/American Standard available;
  2. Specified model and color to clarify for different gases;
  3. Build-In Maintenance Valve
  4. Easy for installation;
  5. 100% tested for gas leakage
  6. With CE and ISO 13485 certificate

BS Type Oxygen, Vacuum, and Medical Air Gas Supply Outlets

The medical central gas supply system plays a significant role in modern hospitals. The appropriate design and setup of medical gas equipment are essential for the hospitals to ensure medical quality, as well as to save the lives and ease the pain of patients in a timely manner. The medical center gas supply system is mainly composed of the gas station, gas pipelines, medical gas monitoring and alarming system, bed head unit, gas terminal, electrical system, medical calling system and auxiliary equipment system.
BS Type Oxygen, Vacuum, and Medical Air Gas Supply Outlets

Medical gas four safety principles:

Continuous gas supply
Sufficient flow and pressure
Gas identification
Gas Quality
BS Type Oxygen, Vacuum, and Medical Air Gas Supply Outlets

Medical Gas Supply System Pipelines
 

Pipe Material

 

The main oxygen pipeline and the branch pipeline into the room are used of defatted purple copper tube or stainless steel tube. The pipeline inside of bed head unit is using degreased copper pipe.

 

BS Type Oxygen, Vacuum, and Medical Air Gas Supply Outlets
Pipe Setting

 

The gas riser pipe is designed in the pipeline well. Pipes should be piped when crossing the wall. The pipes installation should be neat and beautiful.

 

Pipe Connection

 

Pipe system using welded connection. Metal seals throughout the pipe system connection Horizontal pipe and branch pipe of bed head unit should be with maintenance valve

 

Pipe Grounding

 

Medical gas pipelines in medical rooms should be equipotential grounded; mainfold/pipelines etc should be anti-static grounded; Independent grounding resistance should less than 10Ω;

 

Pipeline Leakage Rate

 

Leakage test of medical gas pipelines when no terminal components are connected, the hourly leakage rate should not exceed 0.05%. According to Chinese standard GB50751-2012


Medical Gas Supply System Fittings
Zone Valve Box
BS Type Oxygen, Vacuum, and Medical Air Gas Supply Outlets
Gas Regulator Box
BS Type Oxygen, Vacuum, and Medical Air Gas Supply Outlets

Monitoring alarm box
BS Type Oxygen, Vacuum, and Medical Air Gas Supply Outlets

 

 

 

1,Used to control the on and off of medical gases in the area;

2,1~6 channels of medical gas can be controlled according to user requirements;

3,Silver and copper welding to prevent leakage;

4,Transparent window for easy operation and maintenance;

5,Each gas is marked with a national standard color for easy identification.

1,Used to provide a pressure-stable source of gas for the clinic;

2,With dual circuit design, it can be maintained without stopping the gas;

3,Use a large flow reducer to ensure pressure stability;

4,Emergency door lock device to close the valve in an emergency;

5,Transparent window for easy operation and maintenance;

 

1,Monitor the pressure of the gas supply, and the pressure is high or low to alarm;

2,Monitor the moisture content/oxygen concentration/CO content in oxygen , giving alarm against any deviation from standard set value. Powerful data post-processing function, real-time storage history;

3,intelligent monitoring, with remote data transfer function;

 

 

Medical Gas Supply System Gas Management

The pressure monitoring alarm box is used to monitor the pipeline pressure of the medical center air supply system and respond to pressure changes through a digital microprocessor. When the pressure is higher or lower than the set value, the system will automatically alarm by sound and light, etc., to remind the management to timely process the medical center air supply system.

BS Type Oxygen, Vacuum, and Medical Air Gas Supply Outlets



Comprehensive data collection: monitoring of the source gases and gas-consuming areas in the hospital.
BS Type Oxygen, Vacuum, and Medical Air Gas Supply Outlets
Central monitoring: central monitoring of gas sources and gas-consuming areas, enabling comprehensive data browsing and operation curve analysis.
BS Type Oxygen, Vacuum, and Medical Air Gas Supply Outlets
Fault early warning: abnormal data analysis and trend analysis.
BS Type Oxygen, Vacuum, and Medical Air Gas Supply Outlets


Warranty
The Guarantee/Warranty Period shall be a period of twelve months after on-site startup & commissioning or eighteen months after shipment, whichever occurs first. If any trouble or defect, originating with the design, material, workmanship or operating characteristics of any Goods, arises at any time during GUARANTEE/WARRANTY period, ETR shall, at his own expense and as promptly as possible, make such alterations, repairs and replacements.
On-Site Support
ETR can do paid services of on-site startup, commissioning, installation supervision, training, by providing purchaser with the services of qualified English-speaking
engineer at site. ETR shall obtain all permits and licenses required to perform the services under this Agreement.



FAQ:

Q: Are you factory or trading company?
A: We are factory specilized in making medical equipments from year 2003.

Q: Where are you?
A: We are in ChangSha,Hunan province,3 hours from guangzhou by high-speed rail.

Q: Do you accept the small order?
A: Yes, you can contact with us.

Q: Can we put our logo on your products?
A: Yes, we can customized your logo. But the quantity of the items have special requirements.

Q: What certifications do products have for your company?
A: CE, ISO and SGS at present.

Q: Do you provide technical support?
A: Yes, technical support is available after sales,if needed,we will provide our technicist to overseas to service you.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier